FedQuery
ActivePresolicitationNo Set aside used

Repair Transformer Station 9, Range 301, USAG Bavaria, Grafenwoehr Training Area

DEPT OF DEFENSE › DEPT OF THE ARMY › 0409 AQ HQ CONTRACT

Solicitation #
W912PB26BA1C5I
Posted
Jul 12, 2026
Response deadline
Jul 27, 2026(12d)
Archive date
Aug 11, 2026
NAICS
PSC
Z2NZ
Place of performance
09114
Contact
Jereme Kemp · [email protected]

Description

1. The solicitation will result in a Firm Fixed Price contract with Order of Mangitude of Between $500,000.000 or Less.

2. The performance period is 400 calendar days, whereby a commencement time of 30 calendar days is included.

3. The solicitation will be posted on or about 27 July 2026 with an anticipated bid opening date of approximately 27 August 2026. Paper copies will not be available 4. All responsible sources may submit a bid, which will be considered by the RCO Bavaria.

5. Work will be performed in Germany. Contractor must comply with German law and must have authorization to do business in Germany.

Project: 42A-01014-1P Repair Transformer Station 9, Range 301, USAG Bavaria, GrafenwoehrTraining Area Description of Requirement: 1.4.1 This project specifies the following work: The construction project is located within the Grafenwöhr military training area. - Dismantling of the existing medium-voltage and low-voltage built-in devices in the old transformer station 9, Range 301, consisting of: 1 existing 100 kVA oil transformer, 1 existing medium-voltage switchgear consisting of 3 MV cells, 1 existing low-voltage switchgear, approx. LxHxD = 0.6 m x 2.0 m x 0.6, 1 antenna system (reinstallation in new transformer station), Dismantle all existing medium-voltage cables and low-voltage cables or transfer them to the new station. Dismantle all ceiling lights and switches. Dismantle all existing metal structures. - Demolition of the existing transformer building, LxHxD = 3.15 m x 3,2 m x 2.75 m, building # 30141. - Construction of a new transformer building with cable cellar and pent roof, roof pitch 7 degrees. Building dimensions: approx. 4.2 m x 3.3 m, clear height 2.60 m. Dimensions of reinforced concrete cable cellar approx. 0.8 m high. - Installation of a 24 kV medium-voltage switchgear consisting of: 1 x 24 kV transformer switch panel 2 x 24 kV fused cable outlet 1 x 24 kV reserve panel 1 x 24 kV high-voltage/voltage transformer panel 1 separate 24 kV earth terminal in the transformer room 1 20 kV oil transformer 100 kVA with DGPT2 full transformer protection - Installation of a low-voltage switchgear consisting of: 1 circuit breaker 160 A 1 busbar system 400 A 5 fuse switch disconnectors 63 A 1 energy multimeter with LED display, - Transfer of all medium-voltage and low-voltage cables from the old transformer station 9 to the new transformer station 9. - Creation of a walkable gravel surface for the new transformer station.

View on SAM.gov (attachments & response) ↗

More active opportunities in NAICS 238990

TitleAgencyTypeNAICSPostedDeadline
EDIS: REPAIR STAFF LOT GATE & FENCENATIONAL PARK SERVICESolicitation238990Jul 11, 2026Jul 20, 2026(5d)
N--Services to replace manhole covers & security gateNATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATIONCombined Synopsis/Solicitation238990Jul 10, 2026Jul 16, 2026(1d)
Services to repave parking lots at NWS Atlanta, GANATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATIONCombined Synopsis/Solicitation238990Jul 10, 2026Jul 20, 2026(5d)
El Paso and Big Bend North Tactical Infrastructure (TI) MaintenanceUS CUSTOMS AND BORDER PROTECTIONCombined Synopsis/Solicitation238990Jul 10, 2026Jul 15, 2026(0d)
Repair Underground Tanks at Buildings 454, 580, and 1030, USAG BavariaDEPT OF THE ARMYAward Notice238990Jul 10, 2026