Fire suppression system installation
AGRICULTURE, DEPARTMENT OF › ANIMAL AND PLANT HEALTH INSPECTION SERVICE › MRPBS MINNEAPOLIS MN
Description
Due to a recent fire in building 6418 at Moore Air Base, Texas, a wet fire suppression system is needed. Building 6418 was constructed in the early 1980s with no fire suppression initially. Contractor shall provide design/as-built drawings submittals and installation of a new retrofitted system. The system shall be a turnkey project encompassing everything needed to have a fully functioning fire suppression system. Solicitation documents are posted below.
NOTE: For those wishing to attend the site visit, please send names of attendees to james.g.roloff@usda,gov. A valid drivers license or state ID is required. Amendment 1 is posted below.
RFI: Does Building 6418 currently have an existing fire alarm panel/system that the sprinkler monitoring would tie into? If so, could you please provide the panel/system type, make/model, or any available details needed for a sprinkler monitoring quote? The fire panels are old and obsolete. They will be replaced at another time, but the new sprinkler system must be able to connect to a fire panel in the future. No monitoring is needed. The sign-in sheet for the site visit is posted below. Building drawings posted below. RFIs and responses posted below. Amendment 2 is posted below. It extends the closing date. Amendment 3 is posted below. It extends the closing date. Additional RFIs and responses posted below. Amendment 4 is posted below. There's a change to the response to RFI 6 posted here on August 17. The correct answer is as follows: 6) Please confirm if a CVPC/PEX fire suppression would be sufficient or the USDA prefers schedule 10 or schedule 40 Victaulic black iron piping? Or provide a specification with minimum standards for Moore Airfield that must be met regarding fire suppression piping? It is typical for local building codes and state codes to be of a lesser standard than what a federal installation requires. The statement of work indicates in accordance state and local codes and standards only opening the door for a CVPC system to be priced. The USDA prefers the use of Schedule 40 Victaulic black iron piping.
More active opportunities in NAICS 238220
- FSC WASTEWATER TREATMENT PLANT (WWTP) / DAHLGREN, VA.
- Deadline
- Sep 23, 2026(10d)
- Agency
- DEPT OF THE NAVY
- Type
- Combined Synopsis/Solicitation
- NAICS
- 238220
- Posted
- Sep 11, 2026
- Galley Renovation at USCG Station Lake Tahoe
- Deadline
- Sep 18, 2026(5d)
- Agency
- US COAST GUARD
- Type
- Solicitation
- NAICS
- 238220
- Posted
- Sep 11, 2026
- Replacement of Air Conditioning Units in Nematology Lab
- Deadline
- Sep 22, 2026(9d)
- Agency
- FOREST SERVICE
- Type
- Combined Synopsis/Solicitation
- NAICS
- 238220
- Posted
- Sep 11, 2026
- QHAV and Dehumidification Equipment for Mexican Fruit Fly Eclosion Center in Reynosa, Tamaulipas, Mexico
- Deadline
- Sep 18, 2026(5d)
- Agency
- ANIMAL AND PLANT HEALTH INSPECTION SERVICE
- Type
- Combined Synopsis/Solicitation
- NAICS
- 238220
- Posted
- Sep 10, 2026
- USFS, Southern Research Station, North Building HVAC Repair
- Deadline
- Sep 23, 2026(10d)
- Agency
- FOREST SERVICE
- Type
- Combined Synopsis/Solicitation
- NAICS
- 238220
- Posted
- Sep 10, 2026
| Title | Agency | Type | NAICS | Posted | Deadline |
|---|---|---|---|---|---|
| FSC WASTEWATER TREATMENT PLANT (WWTP) / DAHLGREN, VA. | DEPT OF THE NAVY | Combined Synopsis/Solicitation | 238220 | Sep 11, 2026 | Sep 23, 2026(10d) |
| Galley Renovation at USCG Station Lake Tahoe | US COAST GUARD | Solicitation | 238220 | Sep 11, 2026 | Sep 18, 2026(5d) |
| Replacement of Air Conditioning Units in Nematology Lab | FOREST SERVICE | Combined Synopsis/Solicitation | 238220 | Sep 11, 2026 | Sep 22, 2026(9d) |
| QHAV and Dehumidification Equipment for Mexican Fruit Fly Eclosion Center in Reynosa, Tamaulipas, Mexico | ANIMAL AND PLANT HEALTH INSPECTION SERVICE | Combined Synopsis/Solicitation | 238220 | Sep 10, 2026 | Sep 18, 2026(5d) |
| USFS, Southern Research Station, North Building HVAC Repair | FOREST SERVICE | Combined Synopsis/Solicitation | 238220 | Sep 10, 2026 | Sep 23, 2026(10d) |