Chemical Storage Building
DEPT OF DEFENSE › DEPT OF THE ARMY › W6QM MICC-FT DRUM
Description
The chemical storage building must meet several specifications for construction, safety, and utility. The required minimum dimensions are 42 feet in length, 8 feet in width, and 8 feet 3 inches in height. Access shall be provided by a 60-inch by 80-inch set of double doors, with at least one 36-inch active leaf, centered on one of the 42-foot walls and secured with a padlock-compatible handle. For spill containment, the building must include a sump with a minimum capacity of 1200 gallons.The structure must feature a robust fire-rated design, with walls tested by Intertek for a minimum 4-hour rating and a roof tested for a minimum 3-hour rating. Electrical specifications include a 12-space, 100-amp NEMA 3R main breaker panel (120V/240V), two Class 1, Division 2 explosion-proof LED light fixtures with a switch for the interior, and a dust/vapor-resistant exterior light with a photocell installed outside the hazard zone. Ventilation will be handled by an explosion-proof exhaust system rated for 335 CFM or higher, suitable for petroleum-based storage and compliant with all NFPA/UFC codes, complete with an indicator light and an emergency shut-off switch.For safety and functionality, the building shall be equipped with a grounding kit including an 8-foot ground rod, 10 feet of cable, and a clamp. The interior will be furnished with three-tier, 5-foot-long shelves that are 14 inches deep with a 2-inch lip. A non-perforated, skid-resistant steel ramp, measuring at least 52 inches wide by 72 inches long, must be included. Additionally, the unit shall come with three 10-pound ABC dry chemical fire extinguishers: two installed inside on either side of the door, and one mounted outside in a weatherproof cabinet. The completed chemical storage building is to be delivered to Building P-91, Railroad Street, Fort Drum, NY 13602.
More active opportunities in NAICS 332311
- 5410--Exterior Decontamination Shelter - FARGO VA Medical Facility
- Deadline
- Sep 11, 2026(6d)
- Agency
- VETERANS AFFAIRS, DEPARTMENT OF
- Type
- Solicitation
- NAICS
- 332311
- Posted
- Sep 3, 2026
- Guard Booth - Austin
- Deadline
- Sep 18, 2026(12d)
- Agency
- INTERNAL REVENUE SERVICE
- Type
- Combined Synopsis/Solicitation
- NAICS
- 332311
- Posted
- Sep 3, 2026
- Replace Connex Boxes on Pier
- Deadline
- Sep 8, 2026(3d)
- Agency
- US COAST GUARD
- Type
- Combined Synopsis/Solicitation
- NAICS
- 332311
- Posted
- Sep 3, 2026
- 36C25626Q1319_1 Armored Gatehouses
- Deadline
- Sep 11, 2026(5d)
- Agency
- VETERANS AFFAIRS, DEPARTMENT OF
- Type
- Combined Synopsis/Solicitation
- NAICS
- 332311
- Posted
- Sep 3, 2026
- INTAC Exterior Vehicle Storage Facility (Carport)
- Deadline
- Sep 11, 2026(6d)
- Agency
- DEPT OF THE ARMY
- Type
- Solicitation
- NAICS
- 332311
- Posted
- Sep 3, 2026
| Title | Agency | Type | NAICS | Posted | Deadline |
|---|---|---|---|---|---|
| 5410--Exterior Decontamination Shelter - FARGO VA Medical Facility | VETERANS AFFAIRS, DEPARTMENT OF | Solicitation | 332311 | Sep 3, 2026 | Sep 11, 2026(6d) |
| Guard Booth - Austin | INTERNAL REVENUE SERVICE | Combined Synopsis/Solicitation | 332311 | Sep 3, 2026 | Sep 18, 2026(12d) |
| Replace Connex Boxes on Pier | US COAST GUARD | Combined Synopsis/Solicitation | 332311 | Sep 3, 2026 | Sep 8, 2026(3d) |
| 36C25626Q1319_1 Armored Gatehouses | VETERANS AFFAIRS, DEPARTMENT OF | Combined Synopsis/Solicitation | 332311 | Sep 3, 2026 | Sep 11, 2026(5d) |
| INTAC Exterior Vehicle Storage Facility (Carport) | DEPT OF THE ARMY | Solicitation | 332311 | Sep 3, 2026 | Sep 11, 2026(6d) |